17 year
experience |
| |
|
Programs of analyses
Hardware&software MECOS-C2 system can be used for different
types of biospecimen analyses, as
investigational as special medical standards restricted.
Below
ì
index
denotes techniques for medical purpose,
I
index denotes techniques of
investigational purpose only.
Programs for hematology
Programs for helminth, urine sediment, spermatozoa,
bacterial clumps
analyses
Multipurpose programs
Programs for hematology
Common properties
Efficient
ergonomics, routine operations automation, visual control give advantages in
exactness
above manual
microscopy.
Visual control by a doctor of automated
cell sorting (galleries on a computer monitor) makes possible to correct
quickly galleries compositions with sorting exactness increase up to 100%.
Compact viewing of cells in galleries increases pathological morphology
detection. Integration of flow hemoanalyzer data base is available.
Analyses norm
diapason depending of
patient age is tuned automatically.
Statistics gathering for local norm region definition
is available.
Analysis
results in standard form can be printed and fixed in database.
Database viewing allows to realize
retrospective quality control of specimen preparation and staff mistakes in
analyses results.
Forming of special user menu of cell sorting is available.
The programs
realize quality control of blood smear, using measurements
of erythrocytes staining and layer thinness in sample gathering region.
Complete quality control of automated functions including
visualization of smear screening trajectories and cell
detection in special
reference virtual slide is available.
Staff
teaching using reference virtual slides is available. Statistics can be gathered for
external quality control.
Telepathology, remote consultations are available.
Smear
preparation by spatula or
by
centrifuge are possible.
Options
recommended: smear preparation and staining devices.
|
|
The
ERYTHROCYTE
ANALYSIS
(MECOS-ERAì)
technique
for
complete set
with manual or motorized microscope
performs dialogue microscopy
of stained blood smear. It makes a quantitative evaluation of anysocytosis and poikilocytosis,
builds a Price-Jones graph, distribution of the hemoglobin quantity within
the erythrocytes, distribution of erythrocytes by the shape, the 8 types
formula of the pathological erythrocytes (schizocytes, megalocytes,
echinocytes, stomatocytes, elliptocytes, teardrop cells, target cells, bite
cells), erythrocyte ellipse coefficient.
|
 
|
|
The
BLOOD SMEAR ANALYSIS
(MECOS-BSAì)
program
for
motorized
complete set performs automatic microscopy of a
stained blood smear. BSA scans smear by adaptable path and forms samples of leukocytes
and
erythrocytes of a given volumes. BSA performs a quantitative analyses of erythrocytes as MECOS-ERA technique and calculates the 12 types differential
formula of leukocytes (segmented neutrophyles, lymphocytes, monocytes,
eosinophyles, basophyles, band neutrophyles, blast cells, promyeloblasts,
myeloblasts, metamyelocytes, lymphocyte variant forms, plasma cells). Under 5% of
relocations by a doctor of normal type leukocytes between galleries usually needed
with simply pressing a key. For more details see
MECOS-C2 introduces quality standard of
blood smear analyses
(pdf 3Mb)
|
  
|
|
 
|
|
The
ANIMAL
BLOOD SMEAR ANALYSIS
(MECOS-ABSAì)
program
for
motorized
complete set
is a version of MECOS-BSA for animal blood smear analysis (rat,
mouse, dog, cat, other animals by special order).
|
  |
|
The
HEMO ANALYSIS (MECOS-HEMOì) program
for
motorized
complete set integrates tools of MECOS-BSA and
MECOS-FDMM,
performs additionally large leukocyte sample gathering (up to 5000 cells),
given type leukocyte sample gathering. Lymphocytogram, monocytogram,
neutrophilogram can be calculated.
 |
|
The
RETICULOCYTE
ANALYSIS
(MECOS-RETAì) program for
complete set
with manual or motorized microscope
counts
concentration and distribution of reticulocytes in blood smear.
If motorized, the technique
inputs needed number of field of view in thin part of smear and reticulocyte recognition is performed at multiple focus
positions. Automatically detected reticulocytes and
erythrocytes are marked. Indexes of Reticulocyte
Production (RPI) and Immature Reticulocyte Fraction
(IRF ) are calculated.
|

|
|
The
PLATELET
ANALYSIS
(MECOS-PLAì)
program
for
complete set
with manual or motorized microscope
is analogue of MECOS-RETA and is intended for platelet concentration
and distribution analysis.
Automatically detected
platelets and erythrocytes are marked.
|
 |
|
The
MYELOGRAM
FORMING
(MECOS-MYFì)
technique
for
complete set
with manual or motorized microscope
provides with special menus and blanks of standard myelogram
forming. The program has embedded marrow cells atlas.
|

|
|
The
FLOW HEMOANALYZER INTEGRATION
(MECOS-FHIì)
program
for
motorized MECOS AMS allows to integrate
data of MECOS-BSA and flow hemoanalyzer. |
|
Programs for helminth, urine sediment, spermatozoa,
bacterial clumps
analyses
|
|
The
HELMINTH AND PROTOZOA ANALYSIS
(MECOS-HPAì)
technique
for
complete set
with manual or motorized microscope
is
integration of MECOS-VA and special menus and blanks of standard helminth and protozoa analysis. The program has embedded helminth and protozoa atlas. Ether-formalin precipitation together with PARASEP
test-tubes and FE-2 workstation (DiaSys Corporation)
specimen preparation is recommended.
Options
recommended: specimen preparation (test tubes, workstation).
|

|
|
The
HELMINTH DETECTION
(MECOS-HPDì) technique
for
motorized
complete set
performs
automatic screening of a water, excrement or washout specimen with detection
of helminth eggs and forming of
detected objects gallery for viewing and dialogue classification.
Ether-formalin precipitation together
with PARASEP concentrator tubes and FE-5 workstation (DiaSys
Corporation) specimen preparation is needed. For more details see
MECOS-C2 introduces quality standard of
faecal parasite analyses
(pdf 1Mb)
|

|
|
The
URINE
SEDIMENT ANALYSIS
(MECOS-USAì)
program
for
motorized
complete set
is integration of MECOS-VIM and
special menus and blanks of standard urine sediment analysis. The program has
embedded urine sediment atlas.
Options
recommended: specimen preparation centrifuge.
|

|
|
The
SPERMATOZOA MOBILITY
AND MORPHOLOGY ANALYSIS
technique
(MECOS-SMAI)
for
complete set
with manual or motorized microscope:
processing of video with recording of microscope field of view during
2-10 sec under objective 20x phase contrast, above 0.4 M pixel&30 fps
video resolution;
Dialogue choice of episode of best
spermatozoa motion analysis;
Full number of spermatozoa
measurement;
Spermatozoa mobility parameters
measurements:
VAP -
Average path velocity, mm/s;
VSL -
Straight-line velocity,
mm/s;
VCL -
Curvilinear velocity, mm/s;
ALH -
Amplitude of lateral head displacement,
mm;
BCF -
Beat-cross frequency;
STR -
Straightness VSL/VAP;
LIN -
Linearity VSL/VCL.
4 mobility type spermatozoa sorting
(according WHO).
Morphology analysis of colored sperm:
automated or dialogue detection of
cells; dialogue morphological sorting. |
 |
|
The
BACTERIAL
CLUMPS ANALYSIS
(MECOS-BCAI)
technique for macro viewing counts up automatically
number of bacterial clumps in Petri dish.
The technique works satisfactorily
even clumps have different sizes and partially intersected. Every clump
is marked by red dot and user can control and correct result of
counting. |
 |
|
Multipurpose programs
|
|
The
FLUDENSIMORPHOMETRY
(MECOS-FDMMI)
program
for
complete set with manual or motorized
microscope
provides means of quantitative analysis
of cell and other object morphology, optical density and fluorescent
markers within the specimens of different types. There are means of:
cell objects boundary highlighting (automated of contrast and
semi-automated of poor-contrast boundaries); measurement of more than 20
cell parameters, including optical density, geometrical and textural
characteristics, mutual location, angles, fragment and hole quantities,
max and min diameters, nucleus/cytoplasm ratio, object field of view
concentration.
Color fluorescent markers can be consisted with transmitted light images
and their concentrations inside segmented objects can be calculated.
Other markers such as AgNOR, HER2/neu, Ki-67 also can be segmented and measured.
   |
|
The
FLUDENSIMORPHOMETRY and
DIAGNOSTICS
(MECOS-FDMMDI)
program
in
addition to tools of MECOS-FDMM can form quantitative diagnostic
(differential) decision rules on the base of
measurements of object population of a
teaching specimen samples. Educable neuron nets are used for rules forming. |
|
The
MOBILITY ANALYSIS
(MECOS-MAI) program
for
complete set with manual or motorized
microscope
provides with means of shooting a
real-time movie about mobile objects. Parameters of mobility and space
distribution are calculated.
|
  |
|
The
SCREENING and MOBILITY ANALYSIS
(MECOS-SMAI)
program for
motorized MECOS AMS
provides with means of shooting a real-time
movie about mobile objects. Shooting can be done automatically in selected
points along automatically formed
screening path.
Parameters of mobility and space distribution are calculated. |
|
The
TELEMICROSCOPY
(MECOS-TEMì)
program
for
motorized complete set
provides with means of on-line remote microscope control. Remote expert
can see current field of microscope view on his PC screen and can change
objectives, relocate and focus (autofocus,
multifocus) specimen. Expert can fix and measure objects of a
field of view, form and view trajectory of screening. MECOS-C2 and
expert must be linked by fast line (from 100 Kb/s). |
|
The
SPHEROMETRY
(MECOS-SPHI)
for
complete set
with manual or motorized microscope
realizes automated segmentation and measurement of touching roundish granules forming statistics of diameters.
Measurement error is under 2%. |
  |
|